Our Products
Low Pressure High Air Flow Dust Collector Fan Backward Curved
Low Pressure High Air Flow Backward Curved Dust Collector Fan Introduction G4-10 and series collector fan are suitable for the ventilation and induced draft fan systems of 2~670T/h steam boilers in thermal power plants. The air damper can be used to flexibly adjust the pressure and flow of the fan during operation. It is also possible to select a variable frequency motor, with adjust the pressure and flow of the fan by changing the speed. Fan systems with impeller diameters
HG785 Alloyed Steel V Belt Driven Dust Collector Fan Explosionproof
HG785 Alloyed Steel V-Belt Driven Explosionproof Dust Collector Fan Introduction G4-10 and series dust suction fan are suitable for the ventilation and induced draft fan systems of 2~670T/h steam boilers in thermal power plants. The fan blade placement angle is optimized, more wear-resistant and longer service life. Motor sliding guides are provided for easy tensioning of the belt to reduce energy loss due to belt slack. Technical data series model Rotation Speed (r/min)
Q345 CFB Boiler Long Life Explosion Proof Centrifugal Blower Fan
Q345 CFB Boiler Long Life Explosion Proof Centrifugal Blower Fan Introduction The Q345 CFB Boiler Long Life Explosion Proof Centrifugal Blower Fan is the earliest used fan in China, and it is also the most commonly used fan. The fan speed can be flexibly set by matching different belt pulley diameters to make the fan run at the highest efficiency point and reduce energy waste. The bearing housing uses labyrinth mechanical seal, unique anti-leakage design inside, vent hole at
Stainless Steel Biomass Ventilation Anti-Explosion Boiler Centrifugal Fan
High Temperature Stainless Steel Biomass Boiler Centrifugal Fan Introduction This series of id fan in boiler can also be used for dust removal, mine ventilation and general ventilation systems. The blower delivers air, and the induced draft fan delivers flue gas or gas containing foreign particles. It is capable of outputting a higher outlet pressure while providing more gas flow with lower noise. Stable operation at higher media temperatures.The performance of the fan is
Building Ventilation Dust Collector Fan V Belt Driven Centrifugal Fan
Long Life Building Ventilation V-Belt Driving Dust Collector Fan Introduction The Long Life Building Ventilation V-Belt Driving Dust Collector Fan is generally used for gas transportation of granular or powdery materials, and can be widely used to transport air and non-corrosive non-self-igniting, non-viscous substances. The temperature of the medium generally does not exceed 50°C (max 80°C), the dust and hard particles contained in the medium is not more than 150 mg / m3.
Sintering Heat Dissipation HG785 Steel 2043pa Power Plant Fan
Sintering HG785 Alloyed Steel Heat Dissipation Power Plant Blower Fan Introduction Of Centrifugal Fan Centrifugal fans generally use single-side air intake and use single-stage impellers; those with large flow can be air-intaken on both sides and use two back-to-back impellers, which are also called double-suction centrifugal fans. The principle of gas discharge: When the gas between the blades of the centrifugal fan rotates, the kinetic energy obtained by the centrifugal
V Belt Driving Medium Pressure Explosion Proof Centrifugal Flow Fan
V-Belt Driving Medium Pressure Explosionproof Centrifugal Flow Fan Introduction Mainly to meet the dust emission requirements of the electric arc furnace exhaust gas purification equipment, improve the workshop environment, to ensure that the dust concentration in the electric furnace working area meets the “sanitary standards for industrial enterprises”, and can also be used in various occasions with the same functional requirements. The impeller is annealed to completely
Low Noise Centrifugal Fan Heavy Duty Industrial Blower 1 Year Warranty
Industrial Building Ventilate Single Suction Dust Collector Blower Fan Introduction 1. When the pressure requirement is met, a large gas flow can be output, and the noise is very low. 2. The fan speed can be flexibly set by matching different diameters of belt pulley to make the fan run at the highest efficiency point and reduce energy waste. 3. Motor sliding guides are provided for easy tensioning of the belt to reduce energy loss due to belt slack. 4. When the airflow
Coal Injection Anti Explosion V Belt 1820r/min Centrifugal Ventilation Fans
Coal Injection Anti-Explosion V-Belt Driven Centrifugal Ventilation Fan Blower Introduction It is boiler induced draft fan with a total internal pressure efficiency of 90.5% specially designed to be suitable for various coal quality and equipped with a smoke-and-dust removal device (1~20 tons/hour). This type of fan is currently used in the boiler industry. The air volume of the induced draft fan and the difference in wind pressure are relatively large, in order to adapt to
High Strength Steel Induced Draft Fan With Flat Performance Curve
Q345 High Strength Steel Induced Draft Industrial Blower Fan Introduction The 6-11 series have the characteristics of high efficiency, flat performance curve, wear resistance, and work stability. It has excellent performance and can output high pressure. Q345 High Strength Steel Induced Draft Industrial Blower Fan can be used to transport normal temperature or high temperature non-flammable gases, particles, powder, debris, fibrous materials etc. The fans are commonly used in
High Temp Flue Gas Fan High Pressure Centrifugal Blower Explosion Proof
High Temperature High Pressure Flue Gas Centrifugal Blower Fan Introduction The High Temperature High Pressure Flue Gas Centrifugal Blower Fan is designed for applications requiring high pressure. Under the premise of ensuring a certain amount of air, the full pressure can reach the high pressure requirement. The High Temperature High Pressure Flue Gas Centrifugal Blower Fan is mainly used for blasting furnace blast and other forced air supply, and can also be used for
V Belt Driven Forced Ventilation Explosion Proofing Ac Centrifugal Fan
V-Belt Driven Explosion Proofing Forced Ventilating High Pressure Centrifugal Fan Introduction 9-03 series fan-type iron furnace special high-pressure centrifugal fan, is suitable for IL/h, 2L/h, 3L/h, 3L/h, 7L/h melting rate of iron furnace blast performance requirements. The fan can also be used as the blast for various furnace forging furnaces. It is also suitable for conveying air and non-corrosive, non-self-igniting, non-viscous materials or light powder/debris/short
Single Suction High Air Flow Backward Industrial Exhaust Blower
Single Suction High Air Flow Backward Biomass Boiler Blower Fan Introduction The 4-14 series centrifugal fan is suitable for indoor ventilation in general factories and large buildings. It can be used to input gas as well as to output gas. The gas delivered by the 4-14 series fan should be no more than 80 °C air and other gases that are not self-igniting and are not harmful to the human body and are not corrosive to steel materials. No viscous substances are allowed in the
Foundry Furnace Dust Collector Blower Fan Air Blower For Industrial Use Blue And White
Q345 Coupling Driving Foundry Furnace Antiwear Dust Collector Fan Introduction The Q345 Coupling Driving Foundry Furnace Antiwear Dust Collector Fan has a large flow rate and moderate pressure. This fan is designed for the purpose of using industrial boiler to work in the high-efficiency area and achieve the energy-saving target. The fan is suitable for equipped with economizer (heater) and smoke and dust removal device. It is a high-efficiency energy-saving product jointly
Heavy Duty Centrifugal Fan Heat Dissipation Industrial Dust Blower
Industrial Equipments Heat Dissipation Dust Collector Centrifugal Blower Fan Introduction 1. The Industrial Equipments Heat Dissipation Dust Collector Centrifugal Blower Fan can output high outgas pressure and can work at higher medium temperature, suitable for any industrial occasion where high pressure & high temperature gas needs to be delivered. 2. In the case of common base, the installation is very simple and requires little support from a professional technician. 3.
Induced Draught Fan In Thermal Power Plant Air Exhaust Blower
Power Plant Induced Draught Air Supply Antiwear Exhaust Blower Fan Introduction The 4-10 series ventilation and induced draft fans are suitable for the ventilation and induced draft fan systems of 2~670T/h steam boilers in thermal power plants. Power Plant Induced Draught Air Supply Antiwear Exhaust Blower Fan can also be used for mine ventilation and general ventilation without other special requirements; Mainly used to meet the needs of large air flow applications, low
V-Belt Driving Low Pressure Backward Curved Material Handling Blower
V-Belt Driving Low Pressure Backward Curved Material Handling Blower Introduction The 5-10 series ventilator is a high efficiency and energy saving product developed by our company, which is used for ventilation and exhaust system of smelting, chemical, medicine and dust removal production lines. The fan speed can be flexibly set by matching different belt pulley diameters to make the fan run at the highest efficiency point and reduce energy waste. Motor slide guide can be
Double Inlet Ventilation 3187pa Induced Draft Fan Boiler
Double Inlet Efficient Energy-Saving Ventilation Induced Draft Fan Introduction: The 4-09 series large-flow centrifugal fan is the earliest used fan in China, and it is also the most commonly used fan. Suitable for conveying clean air or light materials at normal temperature, most commonly used in industrial furnaces for air supply, light particle/powder/crush/fiber transportation, air drying/cooling of materials, ventilation and smoke exhaust, and other areas. No viscous