logo

Customized High Volume High Efficiency Boiler Induced Draft Fan with Heat Resistant Design

Customized High Volume High Efficiency Boiler Induced Draft Fan with Heat Resistant Design
Brand Name
SIMO BLOWER
Product Model
7-05Series Double-suction F-type
Certificate
CE/ISO9001/ISO45001
Country Of Origin
Henan, China
MOQ
≥1 set
Unit Price
$500-1,00000.00/set
Payment Method
L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Capacity
300sets 30days
Product Details
Highlight:

Customized high-volume boiler fans

,

High-efficiency induced draft fans

,

Heavy duty centrifugal boiler fans

Product: High-efficiency Boiler Induced Draft Fans
Application: Industrial Kiln Systems
Mounting:: FREE STANDING
Power: Low, Medium, High
Blade Type: Forward, Backward
Customized Suppor: OEM, ODM
Warranty: 1 Year
Product Description
Detailed Specifications And Features
Customized High-Volume and High-Efficiency Boiler Induced Draft Fans

Our custom-designed, high-volume, high-efficiency boiler induced draft fans are specifically engineered for large industrial boiler systems requiring reliable flue gas extraction and optimized energy efficiency. This series maintains stable negative pressure in boiler systems while handling high-temperature exhaust gases, ensuring combustion efficiency and operational safety.

The precision-designed impeller utilizes advanced aerodynamic profiles to maximize flow capacity while minimizing energy consumption. Constructed with heat-resistant materials and reinforced structural support, it withstands continuous thermal stress, corrosive flue gas composition, and varying load conditions. The heavy-duty bearing system features forced lubrication and cooling options, ensuring long-term reliable operation in demanding boiler applications.

Suitable for power plant boilers, industrial steam generators, waste heat recovery boilers, and biomass boilers—systems requiring continuous high-volume exhaust and superior operating efficiency.

Product Features
  • High fan pressure, especially suitable for 1-20t/h industrial boilers equipped with spiral pipes and multi-tube dust collectors
  • Single suction design with impeller diameters ranging from 400mm to 3000mm
  • Adjustable air outlet positions expressed by casing angles; available in "Left" and "Right" configurations
  • Multiple drive modes: V-belt drive, coupling drive, and double support type
  • High efficiency (86.5% at best working point), high total pressure, low noise, flat performance curve, and wide economical use area with backward plate type blades
Product Parameters
Series no.7-05 seriesFeature selection
PerformanceImpeller diameter400-3000mm
Rotation speed≤3000rpm
Pressure range3160-16540Pa
Flow range2473-484756㎥/h
StructureBlade typeBackward, Straight, Aerofoil type
Impeller supportSWSI, DWDI, Overhung type
Lubrication methodOil bath lubrication, grease lubrication, lubrication oil station (Can be specified)
Cooling methodAir cooling, Water cooling, Oil cooling (Can be specified)
Driven modeDirect driven, Coupling driven, Belt driven (Can be specified)
Gas compositionGas temperatureNormal, Customer request, ≥250℃
Gas characteristicClean gas, Corrosive gas, Particulate dust, High temperature gas, Flammable/explosive gas
System Configuration
ComponentStandardOptions
Motor brandChinese famous brandABB, Siemens, WEG etc (Can be specified)
ImpellerHigh quality carbon steelFRP, Stainless steel, Rubber Lining, Wear-resistant materials, High temperature alloy steel (Can be specified)
Air inlet coneHigh quality carbon steelFRP, Stainless steel, Rubber Lining (Can be specified)
CasingHigh quality carbon steelFRP, Stainless steel, Rubber Lining (Can be specified)
Air damperHigh quality carbon steelFRP, Stainless steel, Rubber Lining (Can be specified)
Main shaftHigh strength carbon steel, Alloy structural steelCan be specified
BearingZWZ, SKF, FAG, NSKCan be specified
Bearing housingCast iron
Foundation boltsGB799-1988
Optional Parts

System base frame, Protective screening, Silencer, Inlet & Outlet flexible connections, Inlet & Outlet counter flange, Air damper, Electric actuator, Shock absorber, Diaphragm coupling, Fluid coupling, Motor rain cover, Temperature sensor, Vibration sensor, Soft starter, Inverter, Special Electrical Motor, System monitoring Instrument.

Please provide the fan operating conditions and parameter information, and our business manager will give you a quote
Customized High Volume High Efficiency Boiler Induced Draft Fan with Heat Resistant Design 0
Driven Mode
Customized High Volume High Efficiency Boiler Induced Draft Fan with Heat Resistant Design 1Customized High Volume High Efficiency Boiler Induced Draft Fan with Heat Resistant Design 2
Process Flow
Customized High Volume High Efficiency Boiler Induced Draft Fan with Heat Resistant Design 3
Factory Scene
Customized High Volume High Efficiency Boiler Induced Draft Fan with Heat Resistant Design 4Customized High Volume High Efficiency Boiler Induced Draft Fan with Heat Resistant Design 5Customized High Volume High Efficiency Boiler Induced Draft Fan with Heat Resistant Design 6Customized High Volume High Efficiency Boiler Induced Draft Fan with Heat Resistant Design 7Customized High Volume High Efficiency Boiler Induced Draft Fan with Heat Resistant Design 8Customized High Volume High Efficiency Boiler Induced Draft Fan with Heat Resistant Design 9
Certifications

Xinxiang Xima Blower Co., Ltd. has passed the national-level integration of industrialization and information technology management system assessment, ISO9001 quality management system certification, ISO14001 environmental management system certification, ISO45001 occupational health and safety management system certification, and CE EU certification.

Customized High Volume High Efficiency Boiler Induced Draft Fan with Heat Resistant Design 10Customized High Volume High Efficiency Boiler Induced Draft Fan with Heat Resistant Design 11Customized High Volume High Efficiency Boiler Induced Draft Fan with Heat Resistant Design 12
Packaging & Shipping
Customized High Volume High Efficiency Boiler Induced Draft Fan with Heat Resistant Design 13
FAQ
Customized High Volume High Efficiency Boiler Induced Draft Fan with Heat Resistant Design 14Customized High Volume High Efficiency Boiler Induced Draft Fan with Heat Resistant Design 15