Our Products
Air Supply Material Handling Blower Stainless Steel High Performance
Coupling Driven Forced Ventilating Material Handling Centrifugal Blower Fan Introduction Coupling Driven Forced Ventilating Material Handling Centrifugal Blower Fan are suitable for the ventilation and induced draft fan systems of 2~670T/h steam boilers in thermal power plants. It can also be used for mine ventilation and general ventilation without other special requirements; Mainly used to meet the needs of large air flow applications, low noise and high efficiency. They
Large Flow Heavy Duty Centrifugal Fans Waste Gas Dust Collecting
Industrial Boiler Waste Gas Dust Collecting Q345 Heavy Duty Centrifugal Fan Introduction The 4-09 series large-flow centrifugal blower fan is suitable for conveying clean air or light materials at normal temperature, most commonly used in industrial furnaces for air supply, light particle/powder/crush/fiber transportation, air drying/cooling of materials, ventilation and smoke exhaust, and other areas. No viscous substances are allowed inside the gas, and the dust and hard
Coupling Driving Heavy Duty Industrial Blower Centrifugal Ventilation Fans
Heavy Duty Air Supply Of Industrial Kilns Coupling Driving Centrifugal Fan Introduction The 5-06 series heavy duty centrifugal blower fan can be used in the feeding system of 2-670t/h steam boiler in thermal power plants, it can also meet the requirements of the high-pressure head performance parameters of the fluidized bed furnace. Heavy Duty Air Supply Of Industrial Kilns Coupling Driving Centrifugal Fan can be used for more than four years when the concentration of
Heat Dissipation Forced Draught Fan In Boiler Centrifugal Exhaust Fan
Industrial Equipments Heat Dissipation Heavy Duty Forced Draught Centrifugal Fan Introduction Mainly to meet the dust emission requirements of the electric arc furnace exhaust gas purification equipment, improve the workshop environment, to ensure that the dust concentration in the electric furnace working area meets the “sanitary standards for industrial enterprises”, and can also be used in various occasions with the same functional requirements. The 5-12 series centrifugal
Smoke Exhaust High Temperature Centrifugal Fan Stainless Steel Blower 3 Phase
Smoke Exhaust High Temperature Stainless Steel Centrifugal Blower Fan Introduction The 9-08 series high pressure centrifugal fan is generally used for forging furnace and high pressure forced ventilation, and can be widely used to transport materials, transport air and non-corrosive, non-self-igniting, non-viscous substances gas. The temperature of the medium generally does not exceed 50 ° C (maximum not more than 80 ° C). The dust and hard particles contained in the medium
Carbon Steel High Pressure Centrifugal Fan High Temperature Blower Fan
High Temperature Carbon Steelhigh Pressure Centrifugal Exhaust Fan Introduction The 9-10 series centrifugal fan can output high gas pressure, suitable for conveying normal or high temperature clean gas/combustible gas/corrosive gas/mixed with a few impurities, light particles/debris/short fiber materials. The most commonly used for forced ventilation, rapid drying, rapid cooling and heat dissipation, cement production line chiller cooling, clinker cooler, circulating
SIMO Blower Single Width Single Inlet Fan Industrial Ventilation
Efficient Energy-Saving Antiwear Dust Collector Centrifugal Blower Fan Introduction The Efficient Energy-Saving Antiwear Dust Collector Centrifugal Blower Fan can output high outgas pressure and can work at higher medium temperature, suitable for any industrial occasion where high pressure & high temperature gas needs to be delivered.In the case of common base, the installation is very simple and requires little support from a professional technician.The bearing housing is
Kilns Cooling Forced Draught Fan Industrial Centrifugal Blower Fan
Kilns Cooling Energy Efficiency Forced Draught Centrifugal Blower Flow Fan Introduction The 7-07 series high-pressure centrifugal flow fan has a high output pressure, can transport normal temperature or high temperature various gases and various forms of materials, and also can be used in harsh working environments. Such as conveying high temperature/harmful/dangerous gas, hard particles, powder, debris, fiber, forced ventilation, industrial dust collectors, air filtration
Forced Draft Of Industrial Rotary Kilns Dust Collector Centrifugal Blower Fan
Forced Draft Of Industrial Rotary Kilns Dust Collector Centrifugal Blower Fan Introduction 1.The Forced Draft Of Industrial Rotary Kilns Dust Collector Centrifugal Blower Fan can output higher outlet pressure and provide more gas flow at the same time, low noise. Stable operation at higher media temperatures. 2. The fan speed can be flexibly set by matching different belt pulley diameters to make the fan run at the highest efficiency point and reduce energy waste. 3. Motor
Large Capacity Process Fans In Cement Plant Q345 Three Phase Blower
Cement Mill Centrifugal Flow Antiwear Q345 Large Capacity Blower Fan Introduction 6-12 series high-pressure heavy-duty centrifugal Flow fan, suitable for conveying non-flammable gas and granule/powder/chip/fiber material at normal temperature or high temperature. The output gas flow is slightly larger than the 6-11 series heavy-duty centrifugal fan, the air volume is large, and the pressure is high, smooth operation, high reliability and long life. Cement Mill Centrifugal
Medium Pressure Centrifugal Type Blower Kilns Cooling Ventilation Green
Kilns Cooling Ventilation Medium Pressure Centrifugal Blower Fan Introduction Medium requirements for 6-08 series Centrifugal Blower fans: The medium to be transported should be non-corrosive, non-flammable, explosive, and free of viscous substances. The dust and hard particles contained in the medium should be no more than 150mg/m3. Medium temperature: The medium temperature of standard fans is not more than 80 °C, the V-belt driving type fan can transport media below 150 °C
Industrial SIMO Centrifugal Ventilation Fans For Waste Heat Recovery Device
Centrifugal Fan Industrial Waste Heat Recovery Device Ventilation Blower Introduction Mainly to meet the dust emission requirements of the electric arc furnace exhaust gas purification equipment, improve the workshop environment, to ensure that the dust concentration in the electric furnace working area meets the “sanitary standards for industrial enterprises”, and can also be used in various occasions with the same functional requirements. The 5-12 series centrifugal fan is
Coal Fired Boiler Ventilation Blowers Industrial High Heat Blower
Coal-Fired Boiler Heat Dissipation Building Ventilation Centrifugal Fan Introduction The 4-10 series ventilation centrifugal and induced draft fans are suitable for the ventilation and induced draft fan systems of 2~670T/h steam boilers in thermal power plants. Coal-Fired Boiler Heat Dissipation Building Ventilation Centrifugal Fan can also be used for mine ventilation and general ventilation without other special requirements; Mainly used to meet the needs of large air flow
Backward Induced Draft Fan In Thermal Power Plant Low Pressure Centrifugal Fan
Backward Efficient Energy-Saving Low Pressure Power Plant Centrifugal Blower Fan Introduction The 4-10 series ventilation and induced draft fans are suitable for the ventilation and induced draft fan systems of 2~670T/h steam boilers in thermal power plants. Backward Efficient Energy-Saving Low Pressure Power Plant Centrifugal Blower Fan can also be used for mine ventilation and general ventilation without other special requirements; Mainly used to meet the needs of large air
Dust Extraction Draft Centrifugal Exhaust Fan High Volume Blue
Dust Extraction Draft High Volume Power Plant Centrifugal Exhaust Fan Introduction The Dust Extraction Draft High Volume Power Plant Centrifugal Exhaust Fan is suitable for indoor ventilation in general factories and large buildings. Dust Extraction Draft High Volume Power Plant Centrifugal Exhaust Fan can be used to input gas as well as to output gas. The gas delivered by the 4-14 series fan should be no more than 80 °C air and other gases that are not self-igniting and are
Backward 16Mn Forced Draft Of Industrial Kilns Flue Gas Centrifugal Blower Fan
Backward 16Mn Forced Draft Of Industrial Kilns Flue Gas Centrifugal Blower Fan Introduction The Backward 16Mn Forced Draft Of Industrial Kilns Flue Gas Centrifugal Blower Fan is the earliest used fan in China, and it is also the most commonly used fan. Suitable for conveying clean air or light materials at normal temperature, most commonly used in industrial furnaces for air supply, light particle/powder/crush/fiber transportation, air drying/cooling of materials, ventilation
SIMO Flue Gas Fan Centrifugal Dust Removal Blower Customized Design
Coupling Driving Efficient Energy-Saving Flue Gas Centrifugal Blower Fan Introduction 1. According to customer performance requirements customized design, and optimized by CFD technology, the energy consumption is lower than similar models. 2. For the material of impeller and main spindle, we will choose high-strength carbon steel, low-alloy steel, high-temperature alloy steel, high temperature high-strength alloy steel for different working conditions temperature and working
Oven Wall Cooling Exhaust Duct Flue Gas Blower Fan
Oven Wall Cooling High Quality Exhaust Duct Flue Gas Blower Fan Introduction The 5-06 series fan can be used in the feeding system of 2-670t/h steam boiler in thermal power plants, it can also meet the requirements of the high-pressure head performance parameters of the fluidized bed furnace. The Oven Wall Cooling High Quality Exhaust Duct Flue Gas Blower Fan can be used for more than four years when the concentration of impurities is less than 200 mg/m3. If it contains a lot