Product Details:
Place of Origin: Henan China
Brand Name: SIMO
Certification: CE, ISO9001:2008,TUV
Model Number: SIMO Blower 4-14
Detail Information
Place of Origin:
Henan China
Brand Name:
SIMO
Certification:
CE, ISO9001:2008,TUV
Model Number:
SIMO Blower 4-14
Type:
Centrifugal Fan
Impeller:
Dynamic Balanced
Voltage:
380V/415V/440V/660V/3KV/6KV
Motor:
SIEMENS/ABB/By Your Demand
Noise:
Optional
Color:
Customer's Requirement
Highlight:

High Light

Highlight:

low noise centrifugal fan

,

commercial centrifugal fans

Trading Information
Minimum Order Quantity:
1Set
Price:
300-5000 USD
Packaging Details:
Export Wooden Case Packing, Bare Package
Delivery Time:
15-35 Days
Payment Terms:
T/T, L/C, Payment Term Is Negotiable
Supply Ability:
500 Sets Per Month
Product Description

Coupling Driving Heat Dissipation Antiwear Chemical Industry Blower Fan

 

Introduction

 

The 4-14 series centrifugal fan is suitable for indoor ventilation in general factories and large buildings.It can be used to input gas as well as to output gas.The gas delivered by the 4-14 series fan should be no more than 80 °C air and other gases that are not self-igniting and are not harmful to the human body and are not corrosive to steel materials. No viscous substances are allowed in the gas, and the dust and hard particles contained in the gas are not more than 150 mg/m3.

 

Indoor Low Noise Centrifugal Fan Chemical Exhaust Blowers Industrial 0

 

Application

 

It has large flow and low noise, more use in building ventilation, ventilation and drying of materials, air purification and industrial waste gas treatment, industrial dust collectors, air purification and discharge in hazardous working environments(Paper production line, electrolytic aluminum production line, textile factory...). Blasting of boilers and brick kilns, transport of various gases, transport of granules/powders/debris/fiber materials, etc.

 

Indoor Low Noise Centrifugal Fan Chemical Exhaust Blowers Industrial 1

 

Technical data

 

Series Model

Blower Fan

Rotation Speed
(r/min)

Blower Fan

Total Pressure
(Pa)

Blower Fan

Air Capacity
(m3/h)

Power
(kW)

G4-14

Blower Fan

8D 1450 2177~1481 16985~30134 18.5
9D 960 ~ 1450 824 ~ 2756 16011~42906 11 ~ 30
10D 730 ~ 1450 588 ~ 3403 16701 ~58856 7.5 ~ 55
11.2D 730 ~ 1450 736 ~ 4276 23464 ~82688 11 ~ 90
12.5D 730 ~ 1450 912 ~ 5325 32619 ~114952 22 ~ 160
14D 730 ~ 1450 1147 ~ 6678 45827~161499 37 ~ 315
16D 580 ~ 960 951 ~ 3825 54351~159606 45 ~ 160
           

Y4-14

Blower Fan

8D 1450 1540~1059 15889~29038 15
9D 960 ~ 1450 588 ~ 1952 14978 ~ 41345 7.5 ~ 30
10D 730 ~ 1450 422 ~ 2412 15623 ~ 56715 5.5 ~ 45
11.2D 730 ~ 1450 530 ~ 3020 21950 ~ 79681 11 ~ 75
12.5D 730 ~ 1450 657 ~ 3766 30515 ~ 110772 18.5 ~ 132
14D 730 ~ 1450 824 ~ 4727 42871 ~ 155627 30 ~ 250
16D 580 ~ 960 676 ~ 2707 50844 ~ 153803 45 ~ 132

 

Advantages and Features

 

1. When the pressure requirement is met, a large gas flow can be output, and the noise is very low.

2. The motor selects the high-efficiency energy-saving motor of China's leading motor manufacturing enterprise (can also install the brand motor required by users), the quality is reliable, and the energy consumption is lower.

3. The V-belt drive makes your fan to operate at the optimum speed. Installation is simple and does not require the support of professional technicians.

4. The airflow channel and the impeller are optimized several times, which is more efficient and energy-saving than ordinary large-flow fans.

5. Made of high quality carbon steel, Stainless steel or other metal materials can also be used according to user requirements.

6. The impeller is annealed to completely eliminate structural stresses generated during welding, ensuring that the impeller does not undergo creep and cracking.

1. After the production is completed, all products are tested for running and vibration values for reliable operation.

2. Installation is simple and does not require the support of professional technicians.

 

FAQ

 

1. What parameters need to be provided when you design the industrial centrifugal fans?

Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.

2. How about your company’s pre-sales service and after-sales service?

Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.

3. Does your company have qualifications?

Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.

 