logo

High Temperature Resistant Customizable Design Energy Efficient Induced Draft Fan for Boiler Systems

High Temperature Resistant Customizable Design Energy Efficient Induced Draft Fan for Boiler Systems
Brand Name
SIMO BLOWER
Product Model
4-10
Certificate
CE/ISO9001/ISO45001
Country Of Origin
China
MOQ
1
Unit Price
$500-1000
Supply Capacity
300 Set/Sets per Month centrifugal fan and axial fan manufacturer
Product Details
Highlight:

Induced draft boiler fan

,

Boiler system fan Thailand

,

Industrial draft fan boiler

Bearing: ZWZ, SKF, FAG, NSK,Can Be Specified
System Type: Single Inlet, Overhang Type
Applicable Industries: Manufacturing Plant, Construction Works , Energy & Mining, Industrial Dust Collector System
Voltage: 380V
Power Source: Three Phase AC Motor
After-Sales Service Provided: Field Installation, Commissioning And Training
Lubrication: Oil Bath Lubrication
Company Type: Manufacturer
Warranty: 1 Year
Mounting: FREE STANDING
Product Description
Detailed Specifications And Features
Induced Draft Fan for Boiler System in Thailand
Project Background

The induced draft fan (ID Fan) provided by our company for an industrial boiler system in Thailand has recently been installed, commissioned, and put into operation. This project is applied to a high-temperature flue gas extraction system, which places high demands on the fan's stability, high-temperature resistance, and aerodynamic matching.

The main problems previously faced by the client included: large fluctuations in system load, insufficient efficiency of the existing fan, and poor operational stability.

High Temperature Resistant Customizable Design Energy Efficient Induced Draft Fan for Boiler Systems 0
Operational Performance and Technical Highlights

According to client feedback, the fan is currently operating at approximately 60% of its maximum design speed. The overall system operation is good, and all indicators are stable.

This operational result has significant engineering implications:

  • The fan operates within its high-efficiency range even under partial load
  • The system has a high degree of compatibility, meeting process requirements without requiring full-load operation
  • Energy consumption is significantly reduced, demonstrating good energy-saving potential
  • Sufficient operating margin extends the equipment's service life

This fan not only "works," but achieves system-level optimized operation.

Engineering Solution

Based on the client's operating conditions, our company conducted a customized design from a system matching perspective:

  • Aerodynamic calculations were performed based on boiler flue gas parameters (airflow, pressure, temperature)
  • The impeller structure was optimized to improve efficiency and reduce energy consumption
  • High-temperature resistant materials were selected to ensure long-term stable operation
  • The speed range was controlled to ensure the fan operates within its high-efficiency range

Through systematic design, the fan not only meets the current operating conditions but also possesses a certain load adjustment capability.

Product Parameters

The following data represents partial performance specifications. If you require specific parameters not listed, please contact us for customized design service.

High Temperature Resistant Customizable Design Energy Efficient Induced Draft Fan for Boiler Systems 1
Series no. 4-10 series Feature selection
Performance Impeller diameter 400-3000mm
Rotation speed ≤4000rpm
Pressure range 615-8302Pa
Flow range 10696-952530m³/h
Structure Blade type Backward, Straight, Aerofoil type
Impeller support SWSI, DWDI, Overhung type
Lubrication method Oil bath, grease, lubrication oil station (customizable)
Cooling method Air cooling, Water cooling, Oil cooling (customizable)
Driven mode Direct driven, Coupling driven, Belt driven (customizable)
Gas composition Gas temperature Normal / Custom / ≥250ºC / Custom
Gas characteristic Clean gas / Corrosive gas / Particulate dust / High temperature gas / Flammable/explosive gas
System configuration Motor brand Chinese brands, ABB, Siemens, WEG (customizable)
Impeller Carbon steel / FRP, Stainless steel, Rubber / Wear-resistant materials / High temperature alloy / FRP, Aluminum alloy
Air inlet cone Carbon steel / FRP, Stainless steel, Rubber / Carbon steel / Carbon steel / Carbon steel
Casing Carbon steel / FRP, Stainless steel, Rubber / Carbon steel / Carbon steel / Carbon steel
Air damper Carbon steel / FRP, Stainless steel, Rubber / Carbon steel / Carbon steel / Carbon steel
Main shaft High strength carbon steel, Alloy structural steel (customizable)
Bearing ZWZ, SKF, FAG, NSK (customizable)
Bearing housing Cast iron
Foundation bolts GB799-1988
Option parts System base frame, Protective screening, Silencer, Flexible connections, Counter flange, Air damper, Electric actuator, Shock absorber, Diaphragm coupling, Fluid coupling, Motor rain cover, Temperature sensor, Vibration sensor, Soft starter, Inverter, Special Electrical Motor, System monitoring Instrument.
Product Images
High Temperature Resistant Customizable Design Energy Efficient Induced Draft Fan for Boiler Systems 2
High Temperature Resistant Customizable Design Energy Efficient Induced Draft Fan for Boiler Systems 3
Installation & Manufacturing
High Temperature Resistant Customizable Design Energy Efficient Induced Draft Fan for Boiler Systems 4
High Temperature Resistant Customizable Design Energy Efficient Induced Draft Fan for Boiler Systems 5

Our manufacturing facility operates more than 300 sets of processing and testing equipment with an annual production capacity of 10,000 units. We maintain strict quality control throughout production to ensure zero-error manufacturing and can meet emergency delivery requirements to guarantee your project timelines.

Customer Feedback and Project Value

Customer feedback indicates that "the equipment operates well, and they expressed satisfaction with the fan's performance and stability."

This project verifies that:

  • Our company not only possesses fan manufacturing capabilities but also industrial system matching and optimization capabilities
High Temperature Resistant Customizable Design Energy Efficient Induced Draft Fan for Boiler Systems 6 Send your requirements to receive a tailored recommendation. High Temperature Resistant Customizable Design Energy Efficient Induced Draft Fan for Boiler Systems 7
Packaging & Shipping
High Temperature Resistant Customizable Design Energy Efficient Induced Draft Fan for Boiler Systems 8
Contact Us
High Temperature Resistant Customizable Design Energy Efficient Induced Draft Fan for Boiler Systems 9