V-Belt Driving Smelting Furnace Material Handling Centrifugal Fan
Introduction
The V-Belt Driving Smelting Furnace Material Handling Centrifugal Fan is a high efficiency and energy saving product developed by our company, which is used for ventilation and exhaust system of smelting, chemical, medicine and dust removal production lines.
In the coal-fired boiler system, the ventilation and induce draft systems of various boilers with evaporation capacity of 20 tons/hour to 800 tons/hour can be configured.
V-Belt Driving Smelting Furnace Material Handling Centrifugal Fan can output higher outlet pressure and provide more gas flow at the same time, low noise. Stable operation at higher media temperatures.The fan speed can be flexibly set by matching different belt pulley diameters to make the fan run at the highest efficiency point and reduce energy waste.Motor slide guide can be provided for convenient belt tensioning to reduce energy loss caused by belt slack.
Technical data
series | model |
Centrifugal Fan Rotation Speed |
Centrifugal Fan Total Pressure |
Centrifugal Fan Air Capacity |
Power (kW) |
---|---|---|---|---|---|
5-05 Centrifugal Fan |
4C | 2900 | 1606~1232 | 3007~5152 | 3 |
4.5C | 2880 | 2004~1538 | 4252~7284 | 5.5 | |
5C | 2900 | 2509~1925 | 5873~10062 | 7.5 | |
5.4C | 2900 | 2927~2246 | 7398~12675 | 11 | |
6C | 2500 | 2685~2060 | 8749~14989 | 15 | |
8C | 2000 | 3055~2344 | 16591~28424 | 30 | |
9C | 2000 | 3867~2967 | 23623~40471 | 45 | |
10C | 1600 | 3055~2344 | 25923~44413 | 45 |
Advantages and Features
1.The bearing housing is reserved for the installation position of temperature and vibration sensors, which can facilitate the installation of fan operation monitoring device.
2.Use liquid lubricating oil. It is not necessary to open the bearing housing to replace and fill the lubricating oil. The bearing housing is provided with an observation window for easy observation of the quality and stock of the lubricating oil.
3.The bearing housing uses labyrinth mechanical seal, unique anti-leakage design inside, vent hole at the top, and sealing grease at the joint, completely eliminating the possibility of oil leakage in the bearing hosing.
4.After annealed treatment, the internal stress of the structure generated during welding can be completely eliminated to ensure that the impeller will not creepage and crack.
5. The impeller is subjected to a high standard of dynamic balancing adjusting to ensure stable operation of the fan.
6.After running test and vibration value detection, the operation is reliable.