Send Message

Steam Power Plant Fan Gas Delivery Belt Driven Centrifugal Fan

Basic Information
Place of Origin: Henan China
Brand Name: SIMO
Certification: CE, ISO9001:2008,TUV
Model Number: SIMO Blower 6-03
Minimum Order Quantity: 1 Set
Price: 300-5000 USD
Packaging Details: Export Wooden Case Packing, Steel pallet Packing
Delivery Time: 15-35 Days
Payment Terms: T/T, L/C, Payment Term Is Negotiable
Supply Ability: 500 Sets Per Month
Category: Blower Application: Industrial Ventilation
Feature: High Performance Medium: Clean Air/Dusty Air
After-sales Service Provided: Field Installation, Commissioning And Training Noise: Optional
High Light:

id fan in thermal power plant

,

forced draft fan in thermal power plant

Steam Power Plant Gas Delivery V-Belt Driving Long Life Air Fan

 

Introduction

 

6-03 series medium pressure fans can be used to transport normal temperature or high temperature clean gas, dusty gas, flammable gas, corrosive gas, powder or granular materials, fiber materials, etc.

Mainly used in the industrial field, typical applications are: forced ventilation, forced cooling and heat dissipation, material drying, air purification equipment, industrial dust collector system, air filtration system, flue gas desulfurization, flue gas denitrification, boiler system, kiln system , air supply and induced draught system, industrial boiler primary air fan, secondary air fan, ventilation of various large-scale mill systems (cement mill, coal powder mill, industrial waste heat recovery device, ore powder sintering (sintering machine), Coke production (coking oven), pressurization or decompression sealing of industrial equipment, recovery of industrial waste gas, etc.

Steam Power Plant Gas Delivery V-Belt Driving Long Life Air Fan is the most widely used fan series in the industrial field.

 

Technical data

 

PRODUCT PARAMETERS
Power Plant Fan
Application
Temperature Normal temperature air, Hot air
Air composition Clean air, Dusty air, Corrosive gas, Combustible gas,Powder materials, Light particle materials
Power Plant Fan
Performance
Impeller diameter 400~2500 mm
Speed of mainshaft

≤4000

rpm
Pressure range 732~12086 Pa
Flow range 585~141977 m3/h
Power Plant Fan
Structure
Blade Backward
Impeller support SWSI (Single Width, Single Inlet), Impeller overhung.
Drivetrain V-Belt Can assign
Lubrication Oil bath lubrication
Bearing cooling Air cooling, Water cooling, Oil cooling
Power Plant Fan
System
configuration
Motor ABB, SIEMENS, WEG, TECO, SIMO, Chinese brand…

 

Can assign

Impeller Q235, Q345, SS304, SS316, HG785, DB685...

Casing, Air inlet cone,

Air inlet damper

Q235, Q345, SS304, SS316, HG785, DB685...
Main shaft 45# steel(High-strength carbon structural steel), 42CrMo, Stainless steel...
Bearing FAG, SKF, NSK, ZWZ…
Power Plant Fan
Optional
components
System base frame, Protective screening,Silencer, Inlet & Outlet pipeline compensator,
Inlet & Outlet flange, Damper, Electric actuator, Shock isolator, Diaphragm coupling, Fluid coupling, Motor rain cover, Temperature sensor, Vibrating sensor, Soft starter, Inverter, Special Electrical Motor,System monitoring Instrument, Lube system, Overhead lube tank etc.


Advantages and Features

 

1. It can output higher outlet pressure and provide more gas flow at the same time, low noise. Stable operation at higher media temperatures.

2. The variable inlet damper can be used to flexibly adjust the pressure and flow of the fan during operation. The variable frequency motor can also be selected to adjust the pressure and flow of the fan by changing the speed.

3. Bearing cooling method: according to gas temperature and operating environment conditions choose low-cost water-cooling method or oil-cooling method with good heat dissipation performance. For extremely high temperature operating conditions, can also be installed with an electronic cooler, absolute protection of the reliable operation of the fan system.

4. The material of impeller and main shaft, we will choose high-strength carbon steel, low-alloy steel, high-temperature alloy steel, high temperature &high-strength alloy steel for different working conditions temperature and working speed, so that the impeller and main shaft at high temperature still maintain reliable strength.

 

FAQ

 

1. What parameters need to be provided when you design the industrial centrifugal fans?

Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.

2. How about your company’s pre-sales service and after-sales service?

Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.

3. Does your company have qualifications?

Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.

 

Steam Power Plant Fan Gas Delivery Belt Driven Centrifugal Fan 0

Steam Power Plant Fan Gas Delivery Belt Driven Centrifugal Fan 1

Contact Details
simoblower

Phone Number : +8615637378936

WhatsApp : +8615637378936