The 6-06 series dust exhaust centrifugal fan has the characteristics of low dust accumulation and wear resistant.
It is suitable for discharging gas containing dust, wood chips and finely divided fibers (If it contains hard particles, a dust removal device must be installed in front of the fan.), it can also be used as a general ventilator for ventilation.
Application
Centrifugal fan is widely used in the cement industry, building materials industry, environmental protection industry, metallurgical industry, power industry projects such as large-scale dust collector, industrial boilers, ventilation systems, cooling.
Technical data
Series | Model |
Blower Fan Rotation Speed |
Blower Fan Total Pressure |
Blower Fan Air Capacity |
Power (kW) |
---|---|---|---|---|---|
6-06 Blower Fan |
8D | 1450 | 1859~2745 | 11000~26400 | 15 ~ 22 |
9D | 1450 | 2353~3474 | 15700~37500 | 30 ~ 45 | |
10D | 1450 | 2905~4289 | 21500~51500 | 45 ~ 75 | |
11D | 960 ~ 1450 | 1541~5190 | 22700~68500 | 22 ~ 110 | |
12D | 960 ~ 1450 | 1834~6176 | 24600~89000 | 37 ~ 160 | |
13D | 960 ~ 1450 | 2152~7248 | 31200~113000 | 55 ~ 250 | |
14D | 960 ~ 1450 | 2496~8406 | 39000~141000 | 75 ~ 400 | |
15D | 730 ~ 1450 | 1657~9650 | 36600~172000 | 45 ~ 500 | |
16D | 730 ~ 1450 | 1885~10980 | 44300~211000 | 75 ~ 710 | |
17D | 730 ~ 960 | 2128~5433 | 53200~168000 | 90 ~ 280 | |
18D | 730 ~ 960 | 2386~6091 | 63100~199000 | 110 ~ 355 | |
19D | 730 ~ 960 | 2658~6787 | 74200~234000 | 160 ~ 500 | |
20D | 730 ~ 960 | 2946~7520 | 86700~273000 | 200 ~ 630 | |
21D | 580 ~ 960 | 2050~8290 | 79500~316000 | 200 ~ 800 | |
22D | 580 ~ 960 | 2250~9099 | 92200~363000 | 220 ~ 1000 | |
23.5D | 580 ~ 960 | 2567~10380 | 112000~443000 | 220 ~ 1400 | |
25D | 580 ~ 730 | 6794~6464 | 134000~406000 | 355 ~ 800 | |
26.5D | 480 ~ 730 | 2236~7633 | 132000~483000 | 220 ~ 1120 | |
28D | 480 ~ 730 | 2496~8522 | 156000~569000 | 315 ~ 1400 | |
29.5D | 480 ~ 730 | 2771 ~ 9460 | 183000~667000 | 400 ~ 2000 |
Advantages and Features
1.It can output higher outlet pressure and provide more gas flow at the same time, low noise.
2. The fan speed can be flexibly set by matching different belt pulley diameters to make the fan run at the highest efficiency point and reduce energy waste.
3. Motor slide guide can be provided for convenient belt tensioning to reduce energy loss caused by belt slack.
4. The bearing housing is reserved for the installation position of temperature and vibration sensors, which can facilitate the installation of fan operation monitoring device.
5. Use liquid lubricating oil. It is not necessary to open the bearing housing to replace and fill the lubricating oil. The bearing housing is provided with an observation window for easy observation of the quality and stock of the lubricating oil.
6. The bearing housing uses labyrinth mechanical seal, unique anti-leakage design inside, vent hole at the top, and sealing grease at the joint, completely eliminating the possibility of oil leakage in the bearing hosing.
7. After annealed treatment, the internal stress of the structure generated during welding can be completely eliminated to ensure that the impeller will not creepage and crack.
8. The impeller is subjected to a high standard of dynamic balancing adjusting to ensure stable operation of the fan.
9. After running test and vibration value detection, the operation is reliable.