Coupling Driving Backward Carbon Steel Dust Collector Centrifugal Fan
Detail introduction
6-06 series centrifugal fan is generally used for gas transportation of granular or powdery materials, and can be widely used to transport air and non-corrosive non-self-igniting, non-viscous substances.
The temperature of the medium generally does not exceed 50°C (max 80°C), the dust and hard particles contained in the medium is not more than 150 mg / m3.
Product features
1. According to customer performance requirements customized design, and optimized by CFD technology, the energy consumption is lower than similar models.
2. For the material of impeller and main spindle, we will choose high-strength carbon steel, low-alloy steel, high-temperature alloy steel, high temperature high-strength alloy steel for different working conditions temperature and working speed, so that the impeller and main spindle at high temperature still maintain reliable strength.
3. For dusty gas, we can meet all kinds of working conditions from small amount of dust to large amount of dust. After special treatment, the hardness of blade surface can reach HRC60~70, which can extend the life of the impeller by more than 3 times.
Technical data
series | model | Rotation Speed (r/min) |
Total Pressure (Pa) |
Air Capacity (m³/h) |
Power (kW) |
---|---|---|---|---|---|
6-06 | 8D | 1450 | 1859~2745 | 11000~26400 | 15 ~ 22 |
9D | 1450 | 2353~3474 | 15700~37500 | 30 ~ 45 | |
10D | 1450 | 2905~4289 | 21500~51500 | 45 ~ 75 | |
11D | 960 ~ 1450 | 1541~5190 | 22700~68500 | 22 ~ 110 | |
12D | 960 ~ 1450 | 1834~6176 | 24600~89000 | 37 ~ 160 | |
13D | 960 ~ 1450 | 2152~7248 | 31200~113000 | 55 ~ 250 | |
14D | 960 ~ 1450 | 2496~8406 | 39000~141000 | 75 ~ 400 | |
15D | 730 ~ 1450 | 1657~9650 | 36600~172000 | 45 ~ 500 | |
16D | 730 ~ 1450 | 1885~10980 | 44300~211000 | 75 ~ 710 | |
17D | 730 ~ 960 | 2128~5433 | 53200~168000 | 90 ~ 280 | |
18D | 730 ~ 960 | 2386~6091 | 63100~199000 | 110 ~ 355 | |
19D | 730 ~ 960 | 2658~6787 | 74200~234000 | 160 ~ 500 | |
20D | 730 ~ 960 | 2946~7520 | 86700~273000 | 200 ~ 630 | |
21D | 580 ~ 960 | 2050~8290 | 79500~316000 | 200 ~ 800 | |
22D | 580 ~ 960 | 2250~9099 | 92200~363000 | 220 ~ 1000 | |
23.5D | 580 ~ 960 | 2567~10380 | 112000~443000 | 220 ~ 1400 | |
25D | 580 ~ 730 | 6794~6464 | 134000~406000 | 355 ~ 800 | |
26.5D | 480 ~ 730 | 2236~7633 | 132000~483000 | 220 ~ 1120 | |
28D | 480 ~ 730 | 2496~8522 | 156000~569000 | 315 ~ 1400 | |
29.5D | 480 ~ 730 | 2771 ~ 9460 | 183000~667000 | 400 ~ 2000 |
Application
1. In the factory, the workshops, warehouses and other departments are equipped with centrifugal fans, which play a role in ventilation, ensure the fresh air in the workshop, and help to purify the working environment and the health of employees. At the same time, the factory warehouse is equipped with centrifugal fans to dry the air to ensure that the mechanical equipment or other industrial products maintain the original quality.
2. Install centrifugal fans in mines and tunnels to re-enter fresh air and exhaust dirty air to ensure air circulation in the mines and tunnels.Centrifugal fans can help dust discharge, ensure air transparency in mines and tunnels, and ensure the health of workers in mines and tunnels.
3. A centrifugal fan is installed in the cooling tower, which not only plays the role of ventilation and ensures the normal operation of the cooling tower, but also plays a positive role in improving the cooling effect of the cooling tower by the large flow wind generated by the centrifugal fan.
4. Main ventilator in coal mine is an important equipment to ensure normal ventilation in underground mine, which not only affects the production capacity of coal mine, but also is very important to the safety of mining industry.
5. Centrifugal fans are widely used in boilers and industrial furnaces. They mainly play the role of ventilation and air induction. On the one hand, they ensure the environment of the boiler room or industrial kiln. On the other hand, they allow the replacement of oxygen-enriched air, which makes the firepower of the boiler or kiln more fierce and saves coal to a certain extent. Wait for power resources to reduce enterprise production costs.
FAQ
1. What parameters need to be provided when you design the Heat Dissipation Power Plant Blower Fan?
Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.
If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.
2. How about your company’s pre-sales service and after-sales service?
Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.
After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.
3. Does your company have qualifications?
Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.