Send Message
Home > products >
Power Plant Fan
>
Thermal Power Plant Forward 15955pa Centrifugal Blower Fan

Thermal Power Plant Forward 15955pa Centrifugal Blower Fan

Product Details:
Place of Origin: Henan China
Brand Name: SIMO
Certification: CE, ISO9001:2008,TUV
Model Number: SIMO Blower 9-08
Detail Information
Place of Origin:
Henan China
Brand Name:
SIMO
Certification:
CE, ISO9001:2008,TUV
Model Number:
SIMO Blower 9-08
Bearing:
SKF/FAG/By Your Demand
Motor:
SIEMENS/ABB/By Your Demand
Main Shaft:
High-strength Carbon Structural Steel
Impeller Test:
Ultrasonic Flaw Detection
Delivery Time:
30 Days
Lubrication:
Oil Bath Lubrication
High Light:

High Light

High Light:

Forward Centrifugal Blower Fan

,

15955pa Centrifugal Blower Fan

,

Forward industrial blower fan

Trading Information
Minimum Order Quantity:
1 Set
Price:
Negotiable
Packaging Details:
Export Wooden Case Packing, Steel pallet Packing
Delivery Time:
15-35 Day
Payment Terms:
T/T, L/C, Payment Term Is Negotiable
Supply Ability:
500 Sets Per Month
Product Description

Thermal Power Plant Anticorrosion Forward Centrifugal Blower Fan Machine

 

Centrifugal Fan Of SIMO Blower

 

SIMO Blower has strong technical force, complete testing and experiment equipment, advanced quality inspection methods, sophisticated manufacturing equipment, complete professional fan processing, dynamic balance testing and special molding abrasive tools. The products have achieved standardization and scale to ensure that the performance and quality of the fan meets the requirements of national standards.

 

The appearance of the Thermal Power Plant Anticorrosion Forward Centrifugal Blower Fan Machine has been carefully polished, the surface is smooth, shiny and bright, giving people a comfortable feeling. Adopting advanced design and manufacturing technology in production technology, each process has undergone strict testing and passed CE certification.

 

Intimate humanized service: SIMO provides one-to-one personality design; Make a plan first, and then manufacture after customer satisfaction, so as to fully protect the interests of customers.

 

Technical data

 

series model

Blower Fan

Rotation Speed
(r/min)

Blower Fan

Total Pressure
(Pa)

Blower Fan

Air Capacity
(m³/h)

Blower Fan

Power
(kW)

9-08 7.1C 2900 1063512427 1229219360 75110
8C 14502900 324915955 879227696 18.5200
9C 1450 41814869 1251819717 3045
10C 1450 50656143 1717230052 5575
11.2C 9601450 30317747 1597342221 30132
12.5C 9601450 34509713 2220658695 45250
14C 9601450 434112285 3119782463 75400
16C 9601450 569616250 46569123090 185850

 

 

Product Features

 

  • Centrifugal fan runs smoothly: the optimized design of the impeller reduces the axial force to a minimum, and there is an efficient impeller, and the static and dynamic balance correction makes the whole machine run smoothly. Without any damping device, the bearing Amplitude ≤0.04mm.
  • Low noise: when the blower is running, there is no mechanical friction, and reasonable blade profile is adopted to minimize the noise. The noise produced by centrifugal blower is high frequency noise, which can be soundproofed as long as there are obstacles, so there is almost no noise outside the blower room.
  • Oil-free machinery: blower bearings are lubricated with grease, and the service life of bearings is over three years. The fan does not produce oil and gas during operation. Fans with special requirements use lithium molybdenum disulfide grease to lubricate bearings.
  • The impeller of centrifugal fan adopts special compound line shape, which reduces internal leakage and improves volumetric efficiency.
  • Easy to adjust: the regulating door on the inlet side adjusts the flow rate and the regulating door on the outlet side adjusts the pressure
  • Drive mode: usually a two-pole asynchronous motor, but also a four-pole motor drive. According to different user power grids, motors of different voltages can be used.
  • Sealing: Labyrinth seals are installed on the impeller of each stage except the inlet ring, the interstage and both ends of the casing to prevent gas leakage.
  • Cooling: The bearing seat of the centrifugal fan has two structures: air-cooled and water-cooled. Due to the gradual compression of the gas by the impeller, the temperature of the exhaust casing is much higher than the intake casing. There is an air-cooled or water-cooled device in the exhaust bearing seat to extend the service life of the bearing.

 

FAQ

 

1. What parameters need to be provided when you design the Heat Dissipation Power Plant Blower Fan?

Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.

 

2. How about your company’s pre-sales service and after-sales service?

Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.

 

3. Does your company have qualifications?

Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.

 

Thermal Power Plant Forward 15955pa Centrifugal Blower Fan 0,

Thermal Power Plant Forward 15955pa Centrifugal Blower Fan 1

Thermal Power Plant Forward 15955pa Centrifugal Blower Fan 2