Send Message

Building Ventilation Air Supply Fan Draft Induction Blower 3 Phase

Basic Information
Place of Origin: Henan China
Brand Name: SIMO
Certification: CE, ISO9001:2008,TUV
Model Number: SIMO Blower 5-11
Minimum Order Quantity: 1 Set
Price: 300-5000 USD
Packaging Details: Export Wooden Case Packing, Steel pallet Packing
Delivery Time: 15-35 Days
Payment Terms: T/T, L/C, Payment Term Is Negotiable
Supply Ability: 500 Sets Per Month
Category: Blower Blade: Backward
Impeller Test: Ultrasonic Flaw Detection Main Shaft: High-strength Carbon Structural Steel
Power Source: Three Phase AC Motor Voltage: 380V/415V/440V/660V/6KV/10KV
High Light:

induced draft blower

,

boiler draft fan

Building Ventilation Induced Draft Air Supply Centrifugal Blower Fan

 

Introduction

 

It is boiler induced draft fan with a total internal pressure efficiency of 90.5% specially designed to be suitable for various coal quality and equipped with a smoke-and-dust removal device (1~20 tons/hour).

This type of fan is currently used in the boiler industry. The air volume of the induced draft fan and the difference in wind pressure are relatively large, in order to adapt to the above situation, considering the practicability of the fan, in addition to the 20-ton boiler ID fan need large power coupling direct transmission, the other uses the triangular belt type transmission.

This can use different speeds to meet the requirements of various dust collectors in the same tonnage boiler, combined redundant fan series and machine number.

Building Ventilation Induced Draft Air Supply Centrifugal Blower Fan is used to transport various common gases and hard materials in industrial production, and is suitable for various harsh conditions such as high temperature, wear and corrosion.

 

Technical data

 

PRODUCT PARAMETERS
Centrifugal Blower Fan
Application
Temperature Normal temperature air, Hot air

Air composition

Clean air, Dusty air, Corrosive gas, Combustible gas,Powder materials, Light particle materials
Centrifugal Blower Fan
Performance
Impeller diameter 400~3300

mm

Speed of mainshaft

≤4000

rpm
Pressure range 684~9887 Pa
Flow range

5904~560735

m3/h
Centrifugal Blower Fan
Structure
Blade Backward
Impeller support SWSI (Single Width, Single Inlet), Impeller overhung.
Drivetrain Coupling Can assign
Lubrication Oil bath lubrication
Bearing cooling Air cooling, Water cooling, Oil cooling
Centrifugal Blower Fan
System
configuration
Motor ABB, SIEMENS, WEG, TECO, SIMO, Chinese brand…

 

Can assign

Impeller

Q235, Q345, SS304, SS316, HG785, DB685...

Casing, Air inlet cone,

Air inlet damper

Q235, Q345, SS304, SS316, HG785, DB685...
Main shaft 45# steel(High-strength carbon structural steel), 42CrMo, Stainless steel...
Bearing FAG, SKF, NSK, ZWZ…
Centrifugal Blower Fan
Optional
components
System base frame, Protective screening,Silencer, Inlet & Outlet pipeline compensator,
Inlet & Outlet flange,  Damper, Electric actuator, Shock isolator, Diaphragm coupling, Fluid coupling, Motor rain cover, Temperature sensor, Vibrating sensor, Soft starter, Inverter, Special Electrical Motor,System monitoring Instrument, Lube system, Overhead lube tank etc.

 

 

Advantages and Features

 

1. The bearing cooling method selects a low-cost water-cooling method or an oil-cooling method with better heat dissipation depending on the gas temperature and the conditions of the use environment. For extremely high temperature operating conditions, an electronic cooler can also be added to absolutely protect the reliable operation of the fan system.

2. For the materials of impeller and main shaft, for different working conditions and working speed, we will choose high-strength carbon steel, low-alloy steel, high-temperature alloy steel, high temperature resistant high-strength alloy steel, make the impeller and main shaft to maintain reliable strength at high temperatures.

3. For dust-containing gas, we can meet various working conditions from a small amount of dust to a very large dust content. After special treatment, the surface hardness of the blade can reach HRC60~70, which can extend the life of the impeller by more than 3 times.

4. The bearing housing is reserved for temperature and vibration sensor mounting positions, for convenient to install the fan operation monitoring device.

5. The weld and the main shaft of the impeller are ultrasonic flaw detection to ensure that there are no welding defects and material defects to ensure strength.

6. After the production is completed, all products are tested for running and vibration values for reliable operation.

7. There are a variety of accessories to choose from.

 

FAQ

 

1. What parameters need to be provided when you design the industrial centrifugal fans?

Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.

2. How about your company’s pre-sales service and after-sales service?

Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.

3. Does your company have qualifications?

Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.

 

Building Ventilation Air Supply Fan Draft Induction Blower 3 Phase 0

Building Ventilation Air Supply Fan Draft Induction Blower 3 Phase 1

Contact Details
simoblower

Phone Number : +8615637378936

WhatsApp : +8615637378936