Product Details:
Place of Origin: Henan China
Brand Name: SIMO
Certification: CE, ISO9001:2008,TUV
Model Number: SIMO Blower 8-03
Detail Information
Place of Origin:
Henan China
Brand Name:
SIMO
Certification:
CE, ISO9001:2008,TUV
Model Number:
SIMO Blower 8-03
Type:
Centrifugal Fan
Mounting:
Free Standing
Material:
Carbon Steel/Alloy Steel/Stainless Steel
Impeller Test:
Ultrasonic Flaw Detection
Impeller Support:
SWSI (Single Width, Single Inlet), Impeller Overhung
System Type:
Single Inlet, Overhang Type
High Light:

High Light

High Light:

high pressure centrifugal blower

,

stainless steel centrifugal fan

Trading Information
Minimum Order Quantity:
1 Set
Price:
300-5000 USD
Packaging Details:
Export Wooden Case Packing, Steel pallet Packing
Delivery Time:
15-35 Days
Payment Terms:
T/T, L/C, Payment Term Is Negotiable
Supply Ability:
500 Sets Per Month
Product Description

Industrial Waste Gas Cooling treatment High Pressure Centrifugal Blower Fan

 

Introduction

 

The 8-03 series strong cooling centrifugal fan is designed to work in the high efficiency area to achieve energy saving when operating under variable operating conditions.

Industrial Waste Gas Cooling treatment High Pressure Centrifugal Blower Fan is jointly designed by the fan energy-saving group of the Ministry of Machinery Industry and organized by the national fan industry.

It’s a high-performance product promoted by the State Economic Commission and the Ministry of Machinery Industry.

Industrial Waste Gas Cooling treatment High Pressure Centrifugal Blower Fan has the advantages of high efficiency, low noise, wide performance and high efficiency curve.

Applicable to industrial boilers of 5 ~ 35 tons/hour, the similar intake conditions and performance can be adapted, but the maximum temperature should not exceed 250 °C.

The dust removal device with a dust removal efficiency of not less than 85% must be installed before the induced draft fan, in order to reduce the dust content of the flue gas entering the fan, which not only reduces the pollution of the flue gas to the environment, but also reduces the wear of the dust on the fan. It’s conducive to extending the life of the fan.

 

Technical data

 

PRODUCT PARAMETERS
Centrifugal Fan Application
Temperature Normal temperature air, Hot air
Air composition Clean air, Dusty air, Corrosive gas, Combustible gas,Powder materials, Light particle materials
Centrifugal Fan Performance
Impeller diameter

400-3500

mm
Speed of mainshaft

≤3000

rpm
Pressure range

2202-13840

Pa
Flow range

4451-315984

m3/h
Centrifugal Fan Structure
Blade

Forward

Impeller support SWSI (Single Width, Single Inlet), Impeller overhung.
Drivetrain

Coupling

Can assign
Lubrication Oil bath lubrication
Bearing cooling Air cooling, Water cooling, Oil cooling
Centrifugal Fan System
Configuration
Motor ABB, SIEMENS, WEG, TECO, SIMO, Chinese brand…

 

Can assign

Impeller Q235, Q345, SS304, SS316, HG785, DB685...

Casing, Air inlet cone,

Air inlet damper

Q235, Q345, SS304, SS316, HG785, DB685...
Main shaft 45# steel(High-strength carbon structural steel), 42CrMo, Stainless steel...
Bearing FAG, SKF, NSK, ZWZ…
Centrifugal Fan Optional
Components
System base frame, Protective screening,Silencer, Inlet & Outlet pipeline compensator,
Inlet & Outlet flange, Damper, Electric actuator, Shock isolator, Diaphragm coupling, Fluid coupling, Motor rain cover, Temperature sensor, Vibrating sensor, Soft starter, Inverter, Special Electrical Motor,System monitoring Instrument, Lube system, Overhead lube tank etc


Advantages and Features

 

1. It is capable of outputting higher gas pressures and providing more gas flow with lower noise.

2. In the case of common base, the installation is very simple and requires little support from a professional technician.

3. The motor shaft is elastically connected with the drive shaft, and it is not necessary to constantly tighten the belt or replace the belt, and the maintenance workload is small.

4. The centrifugal Fans with an impeller diameter of less than 1400 mm operate at a normal temperature fan system, eliminating the need for additional bearing cooling devices, reducing the amount of user investment and maintenance.

5. When the airflow resistance is increased, the motor load will be automatically reduced and the motor will not be burnt.

6. Industrial Waste Gas Cooling treatment High Pressure Centrifugal Blower Fan is made of high quality carbon steel, stainless steel or other metal materials are available upon request.

7. After the production is completed, after running test and vibration value detection, the operation is reliable.

Industrial High Pressure Centrifugal Fan Air Blower For Sewage Treatment Plant 0

Industrial High Pressure Centrifugal Fan Air Blower For Sewage Treatment Plant 1