Send Message
Home > products >
Power Plant Fan
>
Low Noise Smoke Exhaust Explosion Proof Blower Fan For Biomass Fuel Power Plant

Low Noise Smoke Exhaust Explosion Proof Blower Fan For Biomass Fuel Power Plant

Product Details:
Place of Origin: Henan China
Brand Name: SIMO
Certification: CE, ISO9001:2008,TUV
Model Number: SIMO Blower 9-11
Detail Information
Place of Origin:
Henan China
Brand Name:
SIMO
Certification:
CE, ISO9001:2008,TUV
Model Number:
SIMO Blower 9-11
Category:
Blower
Feature:
High Performance
Medium:
Clean Air/Dusty Air
Delivery Time:
30 Days
Material:
Carbon Steel/Alloy Steel/Stainless Steel
Blade:
Backward
High Light:

High Light

High Light:

id fan in thermal power plant

,

forced draft fan in thermal power plant

Trading Information
Minimum Order Quantity:
1 Set
Price:
300-5000 USD
Packaging Details:
Export Wooden Case Packing, Steel pallet Packing
Delivery Time:
15-35 Days
Payment Terms:
T/T, L/C, Payment Term Is Negotiable
Supply Ability:
500 Sets Per Month
Product Description

Biomass Fuel Power Plant Smoke Exhaust Anti-Explosion Air Blower Fan

 

Introduction

 

The 9-08 series has the characteristics of high efficiency, low noise, flat performance curve and wide efficient area.

Industrial boilers of 5 ~ 35 tons/hour can be used, those with similar intake conditions and suitable performance can be used, but the maximum temperature shall not more than250°C.

Before the induced draft fan, dust removal device with a dust removal efficiency of no less than 85% must be installed to reduce the dust content of the smoke entering the fan.

Biomass Fuel Power Plant Smoke Exhaust Anti-Explosion Air Blower Fan can not only reduce the pollution of the smoke on the environment, but also reduce the wear of the smoke on the fan, which is conducive to prolonging the life of the fan.

 

Technical data

 

PRODUCT PARAMETERS
Blower Fan
Application
Temperature Normal temperature air, Hot air
Air composition Clean air, Dusty air, Corrosive gas, Combustible gas,Powder materials, Light particle materials
Blower Fan
Performance
Impeller diameter 900~1600 mm
Speed of mainshaft

730~1450

rpm
Pressure range 1412~4835 Pa
Flow range 13189~139712 m3/h
Blower Fan
Structure
Blade Backward
Impeller support SWSI (Single Width, Single Inlet), Impeller overhung.
Drivetrain Coupling Can assign
Lubrication Oil bath lubrication
Bearing cooling Air cooling, Water cooling, Oil cooling
Blower Fan
System
configuration
Motor ABB, SIEMENS, WEG, TECO, SIMO, Chinese brand…

 

Can assign

Impeller Q235, Q345, SS304, SS316, HG785, DB685...

Casing, Air inlet cone,

Air inlet damper

Q235, Q345, SS304, SS316, HG785, DB685...
Main shaft 45# steel(High-strength carbon structural steel), 42CrMo, Stainless steel...
Bearing FAG, SKF, NSK, ZWZ…
Blower Fan
Optional
components
System base frame, Protective screening,Silencer, Inlet & Outlet pipeline compensator,
Inlet & Outlet flange, Damper, Electric actuator, Shock isolator, Diaphragm coupling, Fluid coupling, Motor rain cover, Temperature sensor, Vibrating sensor, Soft starter, Inverter, Special Electrical Motor,System monitoring Instrument, Lube system, Overhead lube tank etc.


Advantages and Features

 

1. In the case of using the common base, the installation is very simple and basically does not require the support of professional technicians.

2. The motor shaft is elastically connected with the drive shaft. It is not necessary to tighten the belt or replace the belt frequently, and the maintenance workload is small.

3. The fan system running at normal temperature with an impeller diameter of less than 1400 mm does not require additional configuration of bearing cooling device, which reduces the user's investment and maintenance workload.

4. When the airflow resistance is increased, the motor load will be automatically reduced and the motor will not be burnt.

5.The fan is made of high quality carbon steel, and can also use stainless steel or other metal materials according to customer requirements.

 

FAQ

 

1. What parameters need to be provided when you design the industrial centrifugal fans?

Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.

2. How about your company’s pre-sales service and after-sales service?

Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.

3. Does your company have qualifications?

Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.

 

Low Noise Smoke Exhaust Explosion Proof Blower Fan For Biomass Fuel Power Plant 0

Low Noise Smoke Exhaust Explosion Proof Blower Fan For Biomass Fuel Power Plant 1