Send Message
Home > products >
Induced Draft Fan
>
Industrial Induced Draft Fan In Boiler Harmful Air Exhaust Blower

Industrial Induced Draft Fan In Boiler Harmful Air Exhaust Blower

Product Details:
Place of Origin: Henan China
Brand Name: SIMO
Certification: CE, ISO9001:2008,TUV
Model Number: SIMO Blower 9-03
Detail Information
Place of Origin:
Henan China
Brand Name:
SIMO
Certification:
CE, ISO9001:2008,TUV
Model Number:
SIMO Blower 9-03
Current Type:
AC
Material:
Carbon Steel/Alloy Steel/Stainless Steel
After-sales Service Provided:
Field Installation, Commissioning And Training
Drivetrain:
Coupling Driven
Bearing:
SKF/FAG/By Your Demand
System Type:
Single Inlet, Overhang Type
Highlight:

High Light

Highlight:

induced draft blower

,

boiler draft fan

Trading Information
Minimum Order Quantity:
1 Set
Price:
300-5000 USD
Packaging Details:
Export Wooden Case Packing, Steel pallet Packing
Delivery Time:
15-35 Days
Payment Terms:
T/T, L/C, Payment Term Is Negotiable
Supply Ability:
500 Sets Per Month
Product Description

Harmful Air Emissions Industrial Boiler Exhaust Induced Draft Centrifugal Fan

 

Introduction

 

Harmful Air Emissions Industrial Boiler Exhaust Induced Draft Centrifugal Fan is suitable for conveying air and non-corrosive, unnatural and non-viscous gases.

The temperature of the medium is generally not more than 80°C, and the dust and hard fine particles contained in the medium are not more than 150mg/m3.

The fan can also be used in cement kiln decomposition process, steel smelting and other special occasions use of high temperature fan (use heat resistant & high strength material).

Centrifugal fan is applied in industrial boiler, (centrifugal fan can be applied in industrial boiler,) it also can be applied in industrial kilns, blast furnace, Industrial waste heat recovery device, Electrolytic aluminium production line air purification system and other industrial work environment.

According to fan parameters you need, SIMO can make centrifugal blower fan technical solution for you. So please provide air capacity, pressure range, medium temperature, voltage and other requirements, more details will help us design suitable technical solution for you.

 

Technical data

 

PRODUCT PARAMETERS
Centrifugal Fan
Application
Temperature Normal temperature air, Hot air
Air composition Clean air, Dusty air, Corrosive gas, Combustible gas,Powder materials, Light particle materials
Centrifugal Fan
Performance
Impeller diameter 800~900 mm
Speed of mainshaft 960~2950 rpm
Pressure range 16680~22314 Pa
Flow range 3019~11632 m3/h
Centrifugal Fan
Structure
Blade Forward
Impeller support SWSI (Single Width, Single Inlet), Impeller overhung.
Drivetrain Coupling Can assign
Lubrication Oil bath lubrication
Bearing cooling Air cooling, Water cooling, Oil cooling
Centrifugal Fan
System
configuration
Motor ABB, SIEMENS, WEG, TECO, SIMO, Chinese brand…

 

Can assign

Impeller Q235, Q345, SS304, SS316, HG785, DB685...

Casing, Air inlet cone,

Air inlet damper

Q235, Q345, SS304, SS316, HG785, DB685...
Main shaft 45# steel(High-strength carbon structural steel), 42CrMo, Stainless steel...
Bearing FAG, SKF, NSK, ZWZ…
Centrifugal Fan
Optional
components
System base frame, Protective screening,Silencer, Inlet & Outlet pipeline compensator,
Inlet & Outlet flange, Damper, Electric actuator, Shock isolator, Diaphragm coupling, Fluid coupling, Motor rain cover, Temperature sensor, Vibrating sensor, Soft starter, Inverter, Special Electrical Motor,System monitoring Instrument, Lube system, Overhead lube tank etc.


Advantages and Features

 

1.The fan can output higher gas pressure, and can provide more gas flow at the same time, low noise.

2. In the case of using the common base, the installation is very simple and basically does not require the support of professional technicians.

3. The motor shaft is elastically connected with the drive shaft. It is not necessary to tighten the belt or replace the belt frequently, and the maintenance workload is small.

4. The fan system running at normal temperature with an impeller diameter of less than 1400 mm does not require additional configuration of bearing cooling device, which reduces the user's investment and maintenance workload.

 

FAQ

 

1. What parameters need to be provided when you design the industrial centrifugal fans?

Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.

2. How about your company’s pre-sales service and after-sales service?

Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.

3. Does your company have qualifications?

Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.

Industrial Induced Draft Fan In Boiler Harmful Air Exhaust Blower 0

Industrial Induced Draft Fan In Boiler Harmful Air Exhaust Blower 1