Basic Information
Place of Origin: Henan China
Brand Name: SIMO
Certification: CE, ISO9001:2008,TUV
Model Number: SIMO Blower 4-10
Minimum Order Quantity: 1 Set
Price: 300-5000 USD
Packaging Details: Export Wooden Case Packing, Steel pallet Packing
Delivery Time: 15-35 Days
Payment Terms: T/T, L/C, Payment Term Is Negotiable
Supply Ability: 500 Sets Per Month
Bearing Type: Rolling Bearing Impeller Support: SWSI (Single Width, Single Inlet), Impeller Overhung
Material: Carbon Steel/Alloy Steel/Stainless Steel Drivetrain: Coupling Driven
Bearing: SKF/FAG/By Your Demand Motor: SIEMENS/ABB/By Your Demand
High Light:

forced draught fan

,

process fans in cement plant

,

High Air Flow Induced Draft Fan

Single Suction High Air Flow Thermal Power Plant Cement Centrifugal Fan

Introduction

 

4-10 series ventilation and induced draft fans are suitable for the ventilation and induced draft fan systems of 2~670T/h steam boilers in thermal power plants.

Single Suction High Air Flow Thermal Power Plant Cement Centrifugal Fan can also be used for mine ventilation and general ventilation without other special requirements; Mainly used to meet the needs of large air flow applications, low noise and high efficiency.

They can transport clean gas, dusty gas, flammable gas, corrosive gas, powder or granular materials at normal temperature or high temperature.

Centrifugal fan is applied in industrial boiler, (centrifugal fan can be applied in industrial boiler,) it also can be applied in industrial kilns, blast furnace, Industrial waste heat recovery device, Electrolytic aluminium production line air purification system and other industrial work environment.

According to fan parameters you need, SIMO can make centrifugal blower fan technical solution for you. So please provide air capacity, pressure range, medium temperature, voltage and other requirements, more details will help us design suitable technical solution for you.

 

Technical data

 

series model

Centrifugal Fan

Rotation Speed
(r/min)

Centrifugal Fan

Total Pressure
(Pa)

Centrifugal Fan

Air Capacity
(m³/h)

Power
(kW)

4-10D

Centrifugal Fan

8D 1450 868 ~ 1303 16156 ~ 30993 11 ~ 15
9D 960 ~ 1450 481 ~ 1651 15229 ~ 44128 7.5 ~ 30
10D 730 ~ 1450 343 ~ 2041 15886 ~ 60533 5.5 ~ 37
11D 730 ~ 1450 415 ~ 2474 21144 ~ 80570 11 ~ 55
12D 730 ~ 1450 495 ~ 2949 27451 ~ 104600 11 ~ 110
14D 730 ~ 1450 674 ~ 4029 43591 ~166100 22 ~ 185
16D 580 ~ 960 555 ~ 2293 51699 ~ 164150 45 ~ 132
18D 960 703 ~ 2908 73610 ~ 233730 45 ~ 200
20D 580 ~ 960 868 ~ 3598 100970 ~ 320610 75 ~ 380
22D 480 ~ 960 755 ~ 4256 116000 ~ 434000 125 ~ 600
25D 480 ~ 730 981 ~ 3187 171000 ~ 484000 140 ~ 475
28D 480 ~ 730 1186 ~ 3969 59000 ~ 545000 400 ~ 1000
29.5D 596 ~ 745 2452 ~ 5423 348000 ~ 810000 630 ~ 1250


Advantages and Features

 

1. The air damper can be used to flexibly adjust the pressure and flow of the fan during operation. It is also possible to select a variable frequency motor, with adjust the pressure and flow of the fan by changing the speed.

2. For the material of impeller and main shaft, we will choose high-strength carbon steel, low-alloy steel, high-temperature alloy steel, high temperature resistant high-strength alloy steel under different working conditions temperature and working speed, so that the impeller and main shaft still maintains a reliable strength at high temperature.

3. Fan systems with impeller diameters less than 1400 mm at normal temperature do not require additional bearing cooling devices, reducing users’ investment and maintenance.

4. The impeller is annealed to eliminate the internal stress generated during welding, ensuring that the impeller does not undergo creep and cracks.

5. The weld of the impeller and the main shaft are ultrasonic flaw detection to ensure that there are no welding defects and material defects to ensure strength.

6. The impeller is subjected to a high standard of dynamic balance correction to ensure stable operation of the fan.

FAQ

 

1. What parameters need to be provided when you design the industrial centrifugal fans?

Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.

2. How about your company’s pre-sales service and after-sales service?

Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.

3. Does your company have qualifications?

Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.

 

High Air Flow Induced Draft Fan In Thermal Power Plant Single Suction 0

High Air Flow Induced Draft Fan In Thermal Power Plant Single Suction 1

Contact Details
simoblower

Phone Number : +8615637378936

WhatsApp : +8615637378936