Send Message

Stokerfeed Boiler 20295Pa Power Plant Fan Forced Draft Centrifugal Fan Blower

Basic Information
Place of Origin: Henan China
Brand Name: SIMO
Certification: CE, ISO9001:2008,TUV
Model Number: SIMO Blower 6-06
Minimum Order Quantity: 1 Set
Price: Negotiable
Packaging Details: Export Wooden Case Packing, Steel pallet Packing
Delivery Time: 15-35 Days
Payment Terms: T/T, L/C, Payment Term Is Negotiable
Supply Ability: 500 Sets Per Month
Impeller Support: SWSI (Single Width, Single Inlet), Impeller Overhung Blade: Forward / Backward/Backward Curved
Drivetrain: Direct/Coupling Driven/V-belt Driven Bearing: SKF/FAG/By Your Demand
Main Shaft: High-strength Carbon Structural Steel Medium: Clean Air/Dusty Air
High Light:

20295Pa Power Plant Fan

,

Stokerfeed Boiler Power Plant Fan

,

Stokerfeed Forced Draft fan

Forced Draught Stokerfeed Boiler Power Plant Centrifugal Fan Blower Machine

 

Product features

 

1. According to customer performance requirements customized design, and optimized by CFD technology, the energy consumption is lower than similar models.

2. For the material of impeller and main spindle, we will choose high-strength carbon steel, low-alloy steel, high-temperature alloy steel, high temperature high-strength alloy steel for different working conditions temperature and working speed, so that the impeller and main spindle at high temperature still maintain reliable strength.

3. For dusty gas, we can meet all kinds of working conditions from small amount of dust to large amount of dust. After special treatment, the hardness of blade surface can reach HRC60~70, which can extend the life of the impeller by more than 3 times.

4. The moderate bonding between the components is tight, and the sealing performance is good, ensuring that the output pressure will not be reduced.

5. After annealed treatment, the internal stress of the structure generated during welding can be completely eliminated to ensure that the impeller will not creepage and crack.

6. Ultrasonic flaw detection on the welding seam and main spindle of the impeller to ensure that there are no welding defects or material defects and ensure the strength.

7. The impeller is subjected to a high standard of dynamic balancing adjusting to ensure stable operation of the fan.

8. Test assembly after production is completed to ensure that there is no interference between the components.

9. Provide on-site arrangement and guidance services.

 

Detail introduction:

 

6-06 series centrifugal fan is generally used for gas transportation of granular or powdery materials, and can be widely used to transport air and non-corrosive non-self-igniting, non-viscous substances.

The temperature of the medium generally does not exceed 50°C (max 80°C), the dust and hard particles contained in the medium is not more than 150 mg / m3.

 

Technical specifications:

 

Series no. 6-06 series Feature selection
Normal anti-corrosion wear-resisting High temperature anti-explosion Remarks
Performance Impeller diameter 400-3500mm  
Rotation speed ≤4000rpm  
Pressure range 2419-20295Pa  
Flow range 1087-241061㎥/h  
Structure Blade type Backward, Straight, Aerofoil type  
Impeller support SWSI(Single Width, Single Inlet), DWDI(Double Width, Double Inlet), Overhung type  
Lubrication method Oil bath lubrication, grease lubrication, lubrication oil station Can be specified
Cooling method Air cooling, Water cooling, Oil cooling Can be specified
Driven mode Direct driven, Coupling driven, Belt driven Can be specified
Gas composition Gas temperature Normal Customer request Customer request ≥250℃ Customer request  
gas characteristic Clean gas Corrosive gas Particulate dust High temperature gas Flammable gas, explosive gas  
System configuration Motor brand Chinese famous brand, ABB, Siemens, WEG etc Can be specified
Impeller High quality carbon steel FRP, Stainless steel, Rubber Lining Wear-resistant layer or wear-resistant liner, ceramic patch High temperature high quality alloy steel FRP, Aluminum alloy Can be specified
Air inlet cone High quality carbon steel FRP, Stainless steel, Rubber Lining High quality carbon steel High quality carbon steel High quality carbon steel Can be specified
Casing High quality carbon steel FRP, Stainless steel, Rubber Lining High quality carbon steel High quality carbon steel High quality carbon steel Can be specified
Air damper High quality carbon steel FRP, Stainless steel, Rubber Lining High quality carbon steel High quality carbon steel High quality carbon steel Can be specified
Main shaft High strength carbon steel, Alloy structural steel Can be specified
Bearing ZWZ, SKF, FAG, NSK Can be specified
Bearing housing Cast iron  
Foundation bolts GB799-1988  
Option parts System base frame, Protective screening, Silencer, Inlet & Outlet flexible connections, Inlet & Outlet counter flange, Air damper, Electric actuator, Shock absorber, Diaphragm coupling, Fluid coupling, Motor rain cover, Temperature sensor, Vibration sensor, Soft starter, Inverter, Special Electrical Motor, System monitoring Instrument.

 

SIMO Blower specializes in manufacturing centrifugal fans with high quality and affordable prices, which are loved by new and old customers.

 

FAQ

 

1. What parameters need to be provided when you design the Heat Dissipation Power Plant Blower Fan?

Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.

 

2. How about your company’s pre-sales service and after-sales service?

Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.

 

3. Does your company have qualifications?

Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.

 

Stokerfeed Boiler 20295Pa Power Plant Fan Forced Draft Centrifugal Fan Blower 0

Stokerfeed Boiler 20295Pa Power Plant Fan Forced Draft Centrifugal Fan Blower 1

Stokerfeed Boiler 20295Pa Power Plant Fan Forced Draft Centrifugal Fan Blower 2

Contact Details
simoblower

Phone Number : +8615637378936

WhatsApp : +8615637378936