Project Overview

A reliable air supply and flue gas extraction system is essential to the operation of an industrial fluidized bed boiler. Different process positions require different airflow and pressure conditions, making fan selection an important part of the boiler's auxiliary equipment configuration.

For a 36 t/h fluidized bed boiler project in Inner Mongolia, SIMO Blower supplied three customized centrifugal fans: one primary air fan, one secondary air fan and one induced draft (ID) fan.

Each fan was selected according to its assigned operating duty, with the corresponding auxiliary components and monitoring provisions configured to meet the project specifications.

latest company case about Three Customized Centrifugal Fans for a 36 t/h Fluidized Bed Boiler Project in Inner Mongolia

Three-Fan Configuration for the Boiler System

The equipment package includes three centrifugal fans serving different positions in the boiler air and flue gas system.

1. Primary Air Fan

The primary air fan provides the required air supply for the boiler's primary air system.

  • Model: 1750SWB21D

  • Quantity: 1 unit

  • Airflow: 33,667 m³/h

  • Total Pressure: 13,500 Pa

  • Operating Temperature: 20°C

  • Motor Power: 200 kW

2. Secondary Air Fan

The secondary air fan is configured for the boiler's secondary air supply requirements.

  • Model: 1550SWB21D

  • Quantity: 1 unit

  • Airflow: 27,504 m³/h

  • Total Pressure: 10,705 Pa

  • Operating Temperature: 20°C

  • Motor Power: 132 kW

3. Induced Draft Fan

The induced draft fan handles flue gas extraction from the boiler system. Its selection takes the higher operating temperature and the required system pressure into account.

  • Model: 1950SWB28D

  • Quantity: 1 unit

  • Airflow: 105,295 m³/h

  • Total Pressure: 10,047 Pa

  • Operating Temperature: 150°C

  • Motor Power: 400 kW

The ID fan impeller uses Q420 material with wear-resistant overlay welding to address the specified service conditions.

Matching Different Fan Duties Within One Boiler System

The three fans do not perform the same task. Their airflow, pressure and temperature requirements are determined by their respective positions in the boiler system.

The primary and secondary air fans are configured for separate combustion-air supply duties, while the ID fan is selected for flue gas extraction at a higher operating temperature.

This distinction is important when specifying a complete boiler fan package. Each fan must be assessed against its own operating point rather than selected using a single set of general boiler parameters.

Customized Auxiliary Equipment and Structural Details

In addition to the main fan performance requirements, the project specifications included auxiliary and maintenance-related provisions.

The fan configurations include relevant inspection and maintenance arrangements. The ID fan is equipped with an inspection access door, a DN50 drainage connection with an isolation valve, and a packing-type shaft sealing arrangement.

The ID fan impeller also incorporates wear-resistant overlay welding.

These details are considered alongside the airflow, pressure and temperature requirements when preparing the equipment configuration.

SIMO Blower for Industrial Boiler Fan Packages

Industrial boiler systems require coordinated fan selection across different process duties. Primary air supply, secondary air supply and flue gas extraction each involve different operating conditions.

SIMO Blower manufactures customized centrifugal fans for industrial boilers, combustion air systems and flue gas handling applications.

For boiler projects, our team evaluates the required airflow, pressure, temperature and equipment configuration for each fan position.

Planning a fluidized bed boiler project or replacing existing boiler fans?

Contact SIMO Blower with your boiler capacity, fan duty, airflow, pressure and operating temperature requirements for an initial technical discussion.